SZ/OEMU/29/2/24-25 - Report of tests on four "factory type" brick surface shelters, Richmond Park, March 5th 1942 (Group 6), October 1942
SZ/OEMU/29/2/24-25
Item
Report of tests on four "factory type" brick surface shelters, Richmond Park, March 5th 1942 (Group 6), October 1942
1942
4 leaves
R.C. 355
One unstrengthened, two strengthened, and one reinforced brick shelter were subjected to a 250 kg. bomb exploding 15 feet away and the damage assessed. Contains plan of test site, illustrations of the shelters and the damage, and photographs.
Two copies.
One unstrengthened, two strengthened, and one reinforced brick shelter were subjected to a 250 kg. bomb exploding 15 feet away and the damage assessed. Contains plan of test site, illustrations of the shelters and the damage, and photographs.
Two copies.
-