SZ/OEMU/29/2/2-3 - Penetration tests on model 5-ft shelter roof with model general-purpose and semi-armour-piercing bombs, March 1942
Reference code
SZ/OEMU/29/2/2-3
Level of description
Item
Title
Penetration tests on model 5-ft shelter roof with model general-purpose and semi-armour-piercing bombs, March 1942
Date/s
1942
Quantity & Format
6 leaves
Creator
Road Research Laboratory
Scope and content
R.C. 326
ARP/323/ACW
The shelter roof resisted the penetration of a 250 kg general purpose bomb and a 500 kg semi-armour-piercing bomb, but it succumbed to the 500 kg general-purpose bomb. Describes the design of the shelter roof used.
Two copies.
ARP/323/ACW
The shelter roof resisted the penetration of a 250 kg general purpose bomb and a 500 kg semi-armour-piercing bomb, but it succumbed to the 500 kg general-purpose bomb. Describes the design of the shelter roof used.
Two copies.
-
SZ - Zuckerman Archive
-
SZ/OEMU - Ministry of Home Security, Oxford Extra-Mural Unit
-
SZ/OEMU/29 - [OEMU. CDRC - Shelters, beams, and walls]
-
SZ/OEMU/29/2 - [OEMU. CDRC - Shelters, beams, and walls. File Two]
- SZ/OEMU/29/2/2-3 - Penetration tests on model 5-ft shelter roof with model general-purpose and semi-armour-piercing bombs, March 1942
-
SZ/OEMU/29/2 - [OEMU. CDRC - Shelters, beams, and walls. File Two]
-
SZ/OEMU/29 - [OEMU. CDRC - Shelters, beams, and walls]
-
SZ/OEMU - Ministry of Home Security, Oxford Extra-Mural Unit
