SZ/OEMU/29/1/60-61 - Bulletin B.12. Precautions to be taken when building protective walls in single-storey factories along a line of existing stanchions, 4/2/42
SZ/OEMU/29/1/60-61
Item
Bulletin B.12. Precautions to be taken when building protective walls in single-storey factories along a line of existing stanchions, 4/2/42
1942
7 leaves
Blast pressure
R.C. 311
F.C. 10
States that walls built into stanchions increase the risk of damage as the walls can then transmit horizontal forces and prevent blast pressure equalising itself around the stanchions. New protective walls should be kept separate from the stanchions. Suggests practical methods for such cases. Includes tables and diagrams.
Two copies.
F.C. 10
States that walls built into stanchions increase the risk of damage as the walls can then transmit horizontal forces and prevent blast pressure equalising itself around the stanchions. New protective walls should be kept separate from the stanchions. Suggests practical methods for such cases. Includes tables and diagrams.
Two copies.
-
SZ - Zuckerman Archive
-
SZ/OEMU - Ministry of Home Security, Oxford Extra-Mural Unit
-
SZ/OEMU/29 - [OEMU. CDRC - Shelters, beams, and walls]
-
SZ/OEMU/29/1 - [OEMU. CDRC - Shelters, beams, and walls. File One]
- SZ/OEMU/29/1/60-61 - Bulletin B.12. Precautions to be taken when building protective walls in single-storey factories along a line of existing stanchions, 4/2/42
-
SZ/OEMU/29/1 - [OEMU. CDRC - Shelters, beams, and walls. File One]
-
SZ/OEMU/29 - [OEMU. CDRC - Shelters, beams, and walls]
-
SZ/OEMU - Ministry of Home Security, Oxford Extra-Mural Unit